SX-2000CO Control Output Unit

SX-2000CO Control Output Unit

SX-2000CO Control Output Unit

SX-2000CO

The SX-2000CO is a control output of the matrix system and can be mounted in an EIA equipment rack (1 U size). Multiple units can be decentralized in a whole system. It is equipped with 32 control output channels. The indicators on the front panel monitor the control output line status. Control output status when the CPU turns off can be set. The SX-2000CO has two power inputs and can support a dual-redundant power supply system. By using a stand-alone mode, system can be configured with only the SX-2000CO, SX-2000CI Control input unit and the power supply unit, permitting the contact data of multiple channels to be transmitted to the remote locations with simple wiring.

EN certification

 
Power Source Usable power supply unit: VX-200PS
24 V DC (operational range: 20 V - 40 V DC)
Two power inputs construction enables dual-redundant power supply.
Current Consumption 0.34 A or less (maximum value in the power operating range)
0.29 A or less (when operated on 24 V DC)
Indication Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator
Control Output 32 outputs, no-voltage make contact output, relay contact output
(withstand voltage: 40 V DC, control current: 2 mA to 300 mA),
removable terminal block (6 pins)

CI/CO Link
Input/Output Connector Input: 1 input, Output: 1 output
RJ45 Connector
Connection Cable Shielded Category 5 twisted pair cable (CAT5-STP)
(1 pair of data wire + 1 pair of control wire)
Maximum Cable Distance 800 m (874.89 yd)

Operating Temperature 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 35 % to 80 %RH (no condensation)
Finish Panel: Aluminum, black, alumite
Case: Surface-treated steel plate
Dimensions 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")"
Weight 3.6 kg (7.94 lb)
Accessory Removable terminal plug (6 pins) …16, Removable terminal plug (4 pins) …1,
Rack mounting screw …4


When operating in matrix mode
Power Source Usable power supply unit: AD-011, AD-031B
24 V DC (operational range: 20 V - 40 V DC)
Two power inputs construction enables dual-redundant power supply.
Current Consumption 0.34 A or less (maximum value in the power operating range)
0.29 A or less (when operated on 24 V DC)
Indication Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator
Control Output 32 outputs, no-voltage make contact output, relay contact output
(withstand voltage: 40 V DC, control current: 2 mA to 300 mA),
removable terminal block (6 pins)

CI/CO Link
Input/Output Connector Input: 1 input, Output: 1 output
RJ45 Connector
Connection Cable Shielded Category 5 twisted pair cable (CAT5-STP)
(1 pair of data wire + 1 pair of control wire)
Maximum Cable Distance 800 m (874.89 yd)

Operating Temperature 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 35 % to 80 %RH (no condensation)
Finish Panel: Aluminum, black, alumite
Case: Surface-treated steel plate
Dimensions 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")"
Weight 3.6 kg (7.94 lb)
Accessory Removable terminal plug (6 pins) …16, Removable terminal plug (4 pins) …1,
Removable terminal plug (2 pins) ...1, Rack mounting screw …4


When operating in stand-alone mode
Power Source Usable power supply unit: AD-011, AD-031B
24 V DC (operational range: 20 V - 40 V DC)
Two power inputs construction enables dual-redundant power supply.
Current Consumption 0.34 A or less (maximum value in the power operating range)
0.29 A or less (when operated on 24 V DC)
Indication Control input indicator (32), Power indicator, CPU OFF indicator, FAULT indicator
Control Output 32 outputs, no-voltage make contact output, relay contact output
(withstand voltage: 40 V DC, control current: 2 mA to 300 mA),
removable terminal block (6 pins)
Connection Cable Main Cable: Shielded CPEV cable* or STP Category 5 straight cable
*when connecting the power supply to each unit: 1 pair for data line
  when connecting the power supply only to the SX-2000CI: 1 pair data line and 2 pairs            power line for a redundant power supply system, or 1 pair data line and 1 pair power line      for a non-redundant power supply system
Brach cable: STP Category 5 straight cable (with RJ45 connectors)
Maximum Cable Distance 800 m (874.89 yd)
Maximum Delay Time 300 ms

Operating Temperature 0 ℃ to +40 ℃ (32 ゜F to 104 ゜F)
Operating Humidity 35 % to 80 %RH (no condensation)
Finish Panel: Aluminum, black, alumite
Case: Surface-treated steel plate
Dimensions 482 (W) × 44 (H) × 331.5 (D) mm (18.98 × 1.73" × 13.05")"
Weight 3.6 kg (7.94 lb)
Accessory Removable terminal plug (16 pins) …4, Removable terminal plug (4 pins) …1,
Removable terminal plug (2 pins) …1, Rack mounting screw …4
Option DC Power Supply Panel: AD-011, AD-031B
Terminal Unit: RM-200RJ

Scroll to top